The Graphtec GL100 Voltage & Temperature Input Terminal connects the GL100 for up to 4ch of voltage DC (20mV to 50V as well as 1-5V) and thermocouple (K or T type) temperature measurement.
Key Features:
- Type Of Measurement: Analog Voltage Or Temperature
- Number Of Input Channels: 4
- Input Method: Scans By The Photo-MOS-Relay, All Channels Isolated Input
- Measuring Range Of Voltage: 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V F.S. And 1-5V F.S
- Measuring Accuracy: 0.15 % Of F.S
- Input impedance: 1 M ohms
- Compatible Data Loggers: Graphtec GL100-N | GL100-WL
£295.00 inc. Vat £354.00
£295.00 inc. Vat £354.00
Out of stock
Additional information
Weight | 0.85 kg |
---|---|
Dimensions | 4.6 × 6.6 × 3.6 cm |
Rated Measuring Current | 50 A AC, 100 A AC, 200 A AC |
Add Contact Encoder | |
Model | |
Width | |
Volume | |
Version | |
Type | |
System Type | |
Size | |
Select Option | |
Select Machine | |
Requirements | |
Qty | |
Print Option | |
Plotter Width | |
Plotter Range | |
Magnetic Stripe | |
Add Contactless Encoder | |
Machine Width | |
Machine Wdith | |
Machine Model | |
Machine Format | |
Machine | |
Hopper Type | |
GL100 | |
Feed Option | |
Contactless Encoder | |
Contact Encoder | |
Compatibility | |
Colour | |
Choose Option | |
Add Magnetic Stripe | |
Wifi |
Graphtec GL100 Voltage & Temperature Input Terminal
The Graphtec GL100 Voltage & Temperature Input Terminal connects the GL100 for up to 4ch of voltage DC (20mV to 50V as well as 1-5V) and thermocouple (K or T type) temperature measurement. Each voltage / temperature channel is configurable. Combination of pulse and logic channels can be measured at the same time.
Graphtec GL100 Voltage & Temperature Input Terminal: Specifications
Type of measurement | Analog voltage or Temperature, Logic (signal pattern) or Pulse (instant or accumulated count) |
|
Number of channel | Voltage/Temperature: 4 channels (measurement type for channels can each be separately selected) Logic/pulse: 4 channels (measurement type for channels can be selected as set of 4 channels) |
|
Input method of voltage/temp. | Scans by the photo-MOS-relay, all channels isolated input | |
Measuring range of voltage | 20, 50, 100, 200, 500 mV, 1, 2, 5, 10, 20, 50 V F.S. and 1-5V F.S. | |
Measuring accuracy | 0.15 % of F.S. | |
Input impedance | 1 M ohms | |
Maximum input voltage | Between positive (“+”) and negative (“-“) input terminal: 60 V Between negative (“-“) terminal of channels: 60 V Between negative (“-“) terminal of channel and “GND”: 60 V |
|
Withstand voltage | Between negative (“-“) terminal of channels: 350 V p-p (1 minute) Between negative (“-“) terminal of channel and “GND”: 350 V p-p (1 minute) |
|
Measuring range of temperature | Thermocouple: K type -200 °C to 1370 °C, T type -200 °C to 400 °C | |
Measuring accuracy | K type -200 ≤ TS ≤ -100 °C: ± (0.05% of reading + 2.0 °C) -100 < TS ≤ 1370 °C: ± (0.05% of reading + 1.0 °C) T type -200 ≤ TS ≤ -100 °C: ± (0.1% of reading + 1.5 °C) -100 < TS ≤ 400 °C: ± (0.1% of reading + 0.5 °C) Reference Junction Compensation (R.J.C.): ± 0.5 °C |
|
Burnout checking | Displaying warning when Thermocouple has failed | |
Unit of temperature measurement | Switchable °C and °F | |
Input of Logic/Pulse | Input signal: Voltage or Dry contact signal Voltage input: 0 to +24V (common ground) Dry contact signal: Relay or Solid state relay Threshold voltage: Approx. +2.5V, Hysteresis: Approx. 0.5V (Status of the signal is changed in the 2V and the 2.5V.) |
|
Measuring rage of Pulse | Instant count: up to 200 counts/sampling interval Accumulated count: up to 65535 counts (Accumulated value is reset by starting the data recording or pressing the QUIT key.) |
|
Sampling interval | 0.5, 1, 2, 5, 10, 20, 30 seconds, 1, 2, 5, 10, 20, 30, 60 minutes | |
Length of cable | Approx. 200 mm | |
Operating environment | Temperature: -10 °C to 50 °C Humidity: up to 80 % RH (non condensed) |
|
External dimension [W x D x H] | Approx. 46 x 66 x 36 mm (exclude protrusion) | |
Weight | Approx. 85 g |